The software AnTherm is equipped with extensive Help and Documentation. AnTherm-Blog offers supplemental information. Picture gallery (Picasa) and Video gallery (YouTube) provide visual impression.
This documentation is not only included with the program's installation but it can be also viewed on internet.

We've made efforts to provide documentation suitable for every user - an engineer, architect or student - making the starting the use of an application as easy as possible. Theoretical background of building physics and engineering calculations, used algorithms and procedures but also normative information have found their way into the documentation.

Extensive tutorials enable an easy start for new user leading him through a calculation of a two dimensional and then three dimensional thermal bridge component. The study of examples provides a quick overview of major application's functions. We've selected few common construction components for chosen  simulations and thermal heat/cold bridge analyses. Evaluations of heat stream (heat flux) lines, temperature on component's surfaces or throughout an interior of construction or even evaluations of condensing humidity (dew point) to answer the question about the risk of mould growth have been considered in examples chosen.

Saturday, 26 November 2011

What is the "HARMONIC" Option of AnTherm

The HARMONIC option of AnTherm calculates “harmonic thermal conductivities” of component or building as indicators required for transient building energy simulations based on periodic (harmonic) approach. This also includes PHPP calculations.
Thermal Harmonic Conductivities and further dynamic indicators facilitating heat transport with heat capacity capabilities follow the ISO and EN standard EN ISO 13786.

The harmonic thermal conductivity is given by the amplitude and phase lag of the heat flow which follows periodically changing boundary conditions (either temperatures or heat sources or sinks). Lagging in time with damping of amplitude (attenuation) results from heat storage capability of materials.
Heat losses might lag many months, intermittent heat gains might result also. Cooling infrastructure might become obsolete or overheating can be practically resolved with the building own (heat) capacity.
Transient heat flows are heavily dependent on heat capacity of building components, especially massive, solid or brick walls, slab or ground structures.

The Harmonic option of AnTherm can be seen as a small brother of the much more extensive TRANSIENT-Option of AnTherm.
The purpose of the Harmonic option is to solve transient, periodic heat transmission equation for the 0-th and 1-st harmonic. The 0-th harmonic is the steady state solution of the equation corresponding to mean heat flows under periodic boundary conditions. The 1-st harmonic provides solutions of amplitude and phase lag for the main period, such as day or year.
When power sources are involved AnTherm’s Harmonic option reports Harmonic Heat Distribution Factors (additionally to Harmonic Thermal Conductivities reported for spaces) and are also given by their amplitude and phase lag of the heat flow following the oscillation of respective heat source or sink.

By using the harmonic indicators much better approximation of dynamic thermal behavior of the building can be obtained when compared to simplified steady state approach – even with only one first harmonic of the oscillation.

Exact indicators calculated with AnTherm for any 3 dimensional geometry and arbitrary combination of materials are indispensible replacement for approximations restricted to few simplified geometries only as those provided in ISO 13370.

The strength of the HARMONIC tool relies on the fact, that harmonic thermal conductances (complex number, amplitude and the phase lag) can be calculated without the need to enter nor to know any boundary conditions – harmonic thermal conductances are output just following the steady state thermal conductances L2D, L3D in the respective report. There is also no need to specify or assume any starting boundary conditions as compared to time step based methods.

It is very important to emphasize, that harmonic thermal conductance are characteristic for the object concerned and by that are independent of any boundary conditions. The proper calculation of these harmonic periodic indicators does not need to know nor to apply any boundary conditions. Further evaluation of the behavior of a building component under certain and periodically changing boundary conditions is subject to the “TRANSIENT” Option of AnTherm (higher harmonics, periodic boundary conditions, animation in time and timeline outputs).

Monday, 25 May 2009

AnTherm “talks” English AND German - as it always did!

Several times I was confronted with mistaken interpretation of AnTherm’s language support. On some forums I’ve even read “… ottimo programma ma è in tedesco. Qualcuno potrebbe consigliarmi qualche software di per la valutazione dei ponti termici?”.

AnTherm “talks” English AND German currently. This bilingual ability can be instantly switched within any installation of AnTherm.
Only the setup “speaks” either of the languages – this depends upon the download language choice, but the installation setup does not influence the bilingual property of AnTherm.

AnTherm will automatically talk German only if installed on the system with German language preset as local. Otherwise AnTherm will choose its default language – English.

Thus you can output “Leitwert Matrix” or switch to English and use “the Conductance Matrix”. Same applies to “längenbezogene Wärmeübergangskoeffizient” or “linear thermal transmittance”.